Wire Connection To Access Controller - IDTECK SR10 User Manual

13.56mhz contactless smart card reader/13.56mhz contactless universal smart card reader/ fingerprint-stored smart card id-only reader
Hide thumbs Also See for SR10:
Table of Contents

Advertisement

9. Wire Connection to Access Controller

Make sure the wire connections are correctly done.
† SR10 only
10. Operation
10-1. After the reader is powered on and becomes ready, the red LED will be lit.
10-2. Bring a card close to the reader until the green LED is lit and the buzzer beeps. Then, the reader
transmits the RF card data to the controller and changes the LED color to red for next reading.
10-3. LED Control
To change the LED color, you may connect the LED Control Input (Yellow wire) to the ground.
Then, the green LED changes to red when a proximity card is presented to the reader and, when
the reading is completed, the green LED comes back on for next reading.
10-4. Buzzer Control
When the reader reads a proximity card, only one beep is generated. However, for better
distinction between the OK and Error status, you can set the reader to generate additional beeps.
In order to do that, you may connect the Beeper Control Input (Blue wire) to the ground.
11