Advertisement

Quick Links

User Manual
SR10/30V
RFID Reader

Advertisement

Table of Contents
loading

Summary of Contents for IDTECK SR10/30V

  • Page 1 User Manual SR10/30V RFID Reader...
  • Page 2: Table Of Contents

    Table of contents ............Table of contents .
  • Page 3 SR10/30V ............13 1 WIEGAND output .
  • Page 4: Safety Information

    Safety Information CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK) NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. This symbol indicates that dangerous voltage consisting a risk of electric shock is present within this unit.
  • Page 5 SR10/30V 5. When installing the controller, fasten it securely and firmly. The fall of controller may cause personal injury. 6. Do not place conductive objects (e.g. screwdrivers, coins, metal parts, etc.) or containers filled with water on top of the controller. Doing so may cause personal injury due to fire, electric shock, or falling objects.
  • Page 6: Important Safety Instructions

    SR10/30V IMPORTANT SAFETY INSTRUCTIONS 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water. 6. Clean only with dry cloth. 7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
  • Page 7: Product Introduction

    Product introduction Features This model is an elegant-looking proximity reader that can be easily attached to a metal doorframe or the wall. Featured by the epoxy adhesion and aluminium case, SR10-V / SR30-V is shock-resistant with a high level of weather-proofing in any challenging weather conditions.
  • Page 8: What's Included In Sr10-V

    SR10/30V What's included in SR10-V What's included in SR30-V At a glance Front / Rear Product introduction...
  • Page 9: Cable Color Scheme

    SR10/30V 1. LED Displays the system operation status using red and green indicators. 2. Buzzer Piezo buzzer. 3. Connection Cable Used to connect to the power or I/O cable. 4. Fixing Hole Fixing hole for wall-mounting. 5. Tamper Switch A tamper switch to detect falling from the wall.
  • Page 10: Installation And External Connection

    Installation and external connection Installation Inserted in the doorframe / attached to the wall 1. Two 6-32 or M3 holes are 3.3” (8.38 cm) away from each other vertically; between the two exists one 1/2” hole through which the reader cables are arranged. The midway hole is located 1.7”...
  • Page 11: Precautions On Installation

    SR10/30V Precautions on installation If installing on a metal wall If you install the reader on a metal wall, the read range may be reduced. To avoid this problem, it is recommended to insert the spacer between the metal wall and the reader as shown below.
  • Page 12: External Connection

    SR10/30V External connection Wiring Diagram Installation and external connection...
  • Page 13 SR10/30V Item Cable Wiring Power Supply Unit Connect the DC+12V to the red line. Connect GND to the black line. Wiegand Connection Connect the green line of the product to the Wiegand D0 input port of the controller. Connect the white line of the product to the Wiegand D1 input port of the controller.
  • Page 14: Initialization

    Initialization Basic operations Initial state (when the power is supplied) When you apply power to the reader, it will sound a beep before entering Standby with the red indicator turned on. Using the card Present the card to the reader until you hear a beep and the red indicator turns green. When the reader has transferred the card data to the controller, it returns to Standby with the red indicator turned on and waits for reading the next card.
  • Page 15: Buzzer Control

    SR10/30V Buzzer Control You can control the buzzer of the device at your preference. You can confi gure the I/O settings of the controller so that it sounds a beep. While the buzzer control is working, the product keeps sounding the beep.
  • Page 16: Output Format

    Output format WIEGAND output Timing Diagram Data type Bit 1 : Even Parity (bit2~bit17) ● Bit2~Bit33 : 4 byte ID number ● Bit34 : Odd Parity (bit18~bit33) ● p.13...
  • Page 17: Rs-232 Output

    SR10/30V RS-232 output Output waveform Data type Start (0X02H) Data (10 Char) End (0x03H) START(0X02H) DATA (10 Char) END (0x03H) Check the following settings: Baud Rate : 9600bps Data Bit : 8 Parity Bit : None Stop Bit : 1 LRC: This is the result of XOR operation of each byte from Start to End.
  • Page 18: Troubleshooting

    Troubleshooting Troubleshooting If the product does not function properly, please see the below for trouble shooting. Problem Solution My card is not read 1) Check the rated voltage specifi ed in the user manual and the catalog. properly. 2) Ensure that you are using an ISO14443 Type A card. - Cards of 125 kHz format can not be used.
  • Page 19 SR10/30V Problem Solution manufacturer. If you are using cards from different card makers, the read range (R/R) differs by the card, which is the result of normal operation. 2) If you encounter a different read range (R/R) for each card that is made the same manufacturer, please contact the nearest customer service.
  • Page 20: Product Specifications

    Product specifications Product specifications Item SR10V SR30V Power / Current DC 12V / Max.80mA Reading Time (Card) 30ms Input Port 2ea : External LED Control, External Buzzer Control Output Port 34bit Wiegand LED Indicator 2 Color LED (Red and Green) Beeper Piezo Buzzer Operating Temperature...
  • Page 21: Rma Request

    (Please refer to the IDTECK webpage for more details.) 2. RMA Code will be issued after the RMA Center reviews the RMA request form. 3. Enclose the product along with the RMA Code and send it to IDTECK RMA Center.
  • Page 22 Tel: +82 2 2659 0055 Fax: +82 2 2659 0086 E-mail: webmaster@idteck.com Website: www.idteck.com E-Training Center: http://www.idtecktraining.com IDTECK Production Facility and RMA Center 2F, 89-4, Dodang-Dong, Weonmi-Gu, Bucheon-Si, Gyeonggi-Do 420-130, Korea Tel: +82 2 2659 0055 Fax: +82 2 2659 0086 E-mail: webmaster@idteck.com Website: www.idteck.com...
  • Page 23: Warranty Policy And Limitation Of Liability

    1) to any product which has been dismantled without authorization of IDTECK or/and has a damaged or detached QC label on its back side; 2) to any losses, defects, or damages caused by improper testing, operation, installation, maintenance, modification, alteration, or adjustment;...
  • Page 24 SR10/30V Warranty Policy and Limitation of Liability p.21...
  • Page 25: Back Cover

    The specifications contained in this manual are subject to change without notice at any time. 5F, Ace Techno Tower B/D, 684-1, Deungchon-Dong, Gangseo-Gu, Seoul, 157-030, Korea Tel : +82-2-2659-0055 Fax : +82-2-2659-0086 E-mail : webmaster@idteck.com IDTECK Co., Ltd.

Table of Contents