6.7.2.3
prtfru Command
The Sun Fire V210 and V240 servers maintain a hierarchical list of all field-replacable
units (FRUs) in the system, as well as specific information about various FRUs.
The prtfru command can display this hierarchical list, as well as data contained in
the serial electrically-erasable programmable read-only memory (SEEPROM) devices
located on many FRUs.
CODE EXAMPLE 6-10
prtfru command with the -l option.
CODE EXAMPLE 6-10
# prtfru -l
/frutree
/frutree/chassis (fru)
/frutree/chassis/MB?Label=MB
/frutree/chassis/MB?Label=MB/system-board (container)
/frutree/chassis/MB?Label=MB/system-board/SC?Label=SC
/frutree/chassis/MB?Label=MB/system-board/SC?Label=SC/sc (fru)
/frutree/chassis/MB?Label=MB/system-board/BAT?Label=BAT
/frutree/chassis/MB?Label=MB/system-board/BAT?Label=BAT/battery
(fru)
/frutree/chassis/MB?Label=MB/system-board/P0?Label=P0
/frutree/chassis/MB?Label=MB/system-board/P0?Label=P0/cpu (fru)
/frutree/chassis/MB?Label=MB/system-board/P0?Label=
P0/cpu/F0?Label=F0
CODE EXAMPLE 6-11
command with the -c option.
6-22
Sun Fire V210 and V240 Servers Administration Guide • December 2005
shows an excerpt of a hierarchical list of FRUs generated by the