• "Radar use true EBL reference": When this checkbox is marked, it is assumed that
bearings lines received from the radar(s) are true referenced. If this option is not marked,
TECDIS will perform the necessary adjustments.
• "Arpa is conning referenced": When this checkbox is marked, it is assumed that target
information from Arpa radar is already adjusted to the navigator position. If it is not
marked, TECDIS will perform the necessary adjustments.
• "Monitor inch diagonal": Specify the diagonal size of the monitor here.
• "Backward (gyro-180º)": Checking this box turns the heading value from gyro 180
degrees.
• In the "Alarm" area, you can select whether sound alarms should sound through the PC
speaker in the chart plotter, through the monitor buzzer or through the RCU-018 Control
Unit.
• "Allow Standby Mode": When this option is activated, it will be possible to set TECDIS
in "Standby Mode". In this mode, no audible alarms will be generated. Activating this
option also allows CPA alarms to be disabled in TECDIS.
NOTE: A prominent warning is displayed whenever the "Standby Mode" is active.
• "Alarm if HDT1-HDT2 > 2.5º": When this box is checked, an alarm will be given if the
heading from the two sensors "Heading 1" and "Heading 2" deviates with more than 2.5
degrees.
• If two positioning methods are in use, the button "Erase Secondary past track" allows
you to remove the past track line from the secondary position sensor.
• "NAME" and "MMSI": The name of the vessel and the MMSI number should be
specified in these fields.

3.3.1 Save and restore setup default values

By clicking the button "Save setup default values", all settings in the "Nmea data" and "Size and
sensors" tabs are saved as default settings. If temporary changes to the settings are made later,
the default values can be restored by clicking the button "Restore saved default values".
For future use and to be certain that no misunderstandings may occur regarding the installation
we recommend that the service engineer saves the default setup file to floppy disk or other
media. He can then keep this file in his personal register of TECDIS installations.
The following files should be copied:
• C:\Program files\TECDIS\dta4.setup
• C:\Program files\TECDIS\Telchart.ini
NOTE: When a Service Key is present when TECDIS Setup is closed, a backup copy of the files
specified above are automatically copied to the Service Key.