TECDIS Installation Manual
Activating Replication
Follow these steps to activate Replication:
1. Verify that the requirements for this feature listed above are met.
2. If routes are present on the TECDIS units, select one unit where all routes will be kept
and one TECDIS unit where all routes will be removed.
3. On both TECDIS units, insert the Service Key and exit to Windows.
4. On both TECDIS units, run C:\Program Files\TECDIS\Replication.exe.
5. On the TECDIS unit where all routes should be kept, select "Retain routes on this
TECDIS and activate replication" and press Execute.
6. On the TECDIS unit where all routes should be removed, select "Delete ALL routes on
this TECDIS and activate replication" and press Execute.
7. On both TECDIS units, remove the service dongle and reboot the system.
After both TECDIS units are again operational, all routes from the unit where routes were kept
will be automatically transmitted to the other TECDIS. All further route changes are
automatically reflected on the other TECDIS.
Deactivating Replication
If the replication feature needs to be deactivated, follow these steps:
1. On both TECDIS units, insert the Service Key and exit to Windows.
2. On both TECDIS units, delete the file
C:\Program Files\TECDIS\SetRtReplicateActive.txt.
3. On both TECDIS units, remove the service dongle and reboot the system.