3.5.5 Monitor Calibration and Test

Monitor Calibration Status: Indicates the current status of monitor calibration. The possible
values seen here and steps to rectify any problems are as follows:
Status Message
No serial line to monitor!
Calibration not performed!
Wrong manual calibration file loaded!
Monitor contains wrong automatic calibration!
Automatic calibration loaded but not verified
Manual calibration loaded but not verified
Automatic calibration loaded and verified
Manual calibration loaded and verified
Calibration Name: Indicates the name of the currently loaded manual or automatic calibration.
Monitor Type: Indicates the monitor model name as reported by the monitor during the last
automatic calibration process.
Identify Monitor and Load Automatic Calibration: Initiates automatic identification of
monitor type and attempts to load automatic calibration data from the monitor.
Manual Calibration: Load Calibration File...: Allows the operator to manually load a monitor
calibration file.
Monitor Connection Tests...: Provides access to tests to verify correct monitor serial
connection (buzzer test, backlighting adjustment tests and monitor identification test).
This area provides information on the current
monitor calibration status, means to update the
monitor calibration and diagnostics for testing the
serial connection to the monitor.
Proper monitor calibration is needed to ensure
correct chart colors and symbols.
To calibrate the monitor first attempt automatic
calibration by pressing the "Identify Monitor and
Load Automatic Calibration" button. If this is not
successful, calibrate manually by pressing the
"Manual Calibration: Load Calibration File..."
button and selecting the correct calibration file
matching the monitor. If such a file cannot be
located, this can be obtained from your TECDIS
support provider.
Action
Connect the monitor to a serial port in accordance with chapter
2 and 3.2.
Perform automatic or manual calibration as outlined below.
The manual calibration file loaded does not match the
connected monitor. Obtain the correct calibration file from your
TECDIS support provider and repeat manual calibration.
The monitor does not contain the correct monitor calibration
files. Contact your TECDIS support provider.
Calibration has been successfully performed. Verify correct
calibration by comparing the monitor model specified in
"Calibration Name" to the monitor model label.
Calibration has been successfully performed and verified.