Transmit Warnings - Paradise Datacom Quantum Installation And Operating Handbook

Satellite modem
Table of Contents

Advertisement

Quantum and Evolution Series Installation and Operating Handbook

12.2 Transmit Warnings

Fault Text
Tx
warning:
Maximum
Framer failed to find a frame length to support TS ID
multiframe
period
too
maintenance. Try reducing ESC baud rate or
small.
increasing maximum multiframe period.
Tx
warning:
Frame
A frame backward alarm has been detected at the
backward alarm detected
Tx input. This indicates that equipment downstream
at Tx input, indicating Rx
of the receive path has failed and is returning an
output or downstream Rx
alarm. This may be due to any receive downstream
equipment fault.
equipment, but could be due to the modem Rx
output failing. Check the modem Rx path status and
that the Rx data output from the modem is
connected to the downstream equipment.
Tx warning: TS16 MF
A multiframe backward alarm has been detected at
backward alarm detected
the Tx input indicating that equipment downstream
at Tx input, indicating
of the receive path has failed to find multiframe sync
equipment
downstream
and is returning an alarm. On the Rx path, if the
of Rx has failed to find
Insert Mux bearer is set to Originate, then check the
MF sync.
Rx path is also using CAS, otherwise it will generate
a bearer without a TS16 Multiframe.
Tx
warning:
Cannot
The required BUC output power cannot be
hold/reach power set at
achieved. This alarm is only displayed when the
BUC
modem is in terminal mode & the modem attempts
to set the BUC output power by adjusting it's output
level & a attenuator in the BUC. This can be caused
by too much attenuation in the cross site cabling or
inability to control the attenuator in the BUC (such
as use of a non-Paradise BUC with no input
attenuator)
Tx warning: BUC PSU
The current drawn by the BUC has exceeded the
outside limits.
permissible upper & lower limits.
Tx warning: Tx Channel
Consult technical support if this alarm cannot be
DPLL Unlocked.
cleared.
Tx warning: Tx exceeds
Configuration error, data rate for FEC scheme
4.5Mbps limit in TPC
exceeded.
5/16.
Tx warning: Tx exceeds
Configuration error, data rate for FEC scheme
6.5Mbps limit in TPC
exceeded.
21/44 or 2/3.
Tx warning: Tx exceeds
Configuration error, data rate for FEC scheme
7.7Mbps limit in TPC 1/2.
exceeded.
Tx warning: Tx exceeds
Configuration error, data rate for FEC scheme
12Mbps limit in TPC 7/8.
exceeded.
Tx warning: Tx exceeds
Configuration error, data rate for FEC scheme
33Mbps limit in TCM 2/3.
exceeded.
Tx warning: Tx data rate
Configuration error, data rate for terrestrial interface
outside interface range.
exceeded.
Tx warning: G703 Carrier
Modem is set to use the G703 terrestrial interface
Lost.
but no G703 signal has been detected, check
configuration of G703 interface.
Tx warning: Carrier out of
The carrier frequency selected for the Tx carrier has
range.
exceeded the permissible range for the configured
symbol rate.
Tx warning: Line Code
Line code violations have been detected on the
Violation detected.
G703 interface, check configuration of G703
interface.
Tx warning: Tx symbol
The modems current configuration exceeds the
rate outside range.
permissible symbol rate, check the configuration.
Tx warning: Tx Terrestrial
Consult technical support if this alarm cannot be
DPLL Unlocked.
cleared.
Tx warning: Data clock
The phase of the input clock and data is checked to
inverted, data changing
ensure the data is stable when it is actually latched
state on wrong edge.
into the modem. This message means that the data
is changing at this critical time, and it will cause data
errors. Check the A & B clock lines are not
reversed.
Notes
12-3
Relays To Ter To Sat
D
SB
D
SB/SD
D
CM
CM
CM
CM
D
CM
CM
D
Other

Advertisement

Table of Contents
loading

This manual is also suitable for:

Evolution