Quantum and Evolution Series Installation and Operating Handbook
Edit-Rx-Clocks-Advanced Menu
Advanced:
This menu contains the following options:
•
Auto centre. This controls whether the Rx (Doppler) buffer is centred following an Rx
path recovery from failure.
•
Multiframe sync. This controls whether the Rx buffer should be increased so that the
buffer slip magnitude is an integral number of terrestrial multiframes when necessary,
to maintain multi-frame sync when the buffer slips.
•
Manual centre. This allows the Rx buffer to be recentred manually.
Edit-Rx-Clocks-Advanced-Auto Centre Screen
Centre buffer after failure recovery: [On]
Factory default:
On
Controls whether the Rx buffer is centred following an Rx path recovery
Description:
from failure. This should be disabled where minor outages occur where
the errors or synchronisation losses caused by centring the buffer are
potentially larger than those caused by the outage.
1:Auto centre
2:Multiframe sync
3: Manual centre
1:Off
2:On
7-91