Quantum and Evolution Series Installation and Operating Handbook
1:Setup
4:PCMA
7:AUPC
The Status menu contains the current modem status split over several screens. Note that
the 1-for-N screen is not available unless the modem is the standby modem in a 1-for-N
redundancy switch. The 1-for-N redundancy switch user interface is documented
separately in the document 'Installation and Operating Handbook for Quantum and
Evolution Series Redundancy Switches'.
Status-Setup Screen
Tx:70.0000MHz
2048000bps
4096000sps
This screen is constantly updated with the following information:
•
Transmit carrier frequency
•
Receive carrier frequency
•
Transmit terrestrial data rate
•
Receive terrestrial data rate
•
Transmit symbol rate
•
Receive symbol rate
Status-Traffic Screen
Tx OK since 10:14:46 on 6/4/05
Rx OK since 10:14:46 on 6/4/05
Carrier:Mute-Brk
This screen is constantly updated with the following information:
•
When there is no transmit path fault then the message 'Tx OK since HH:MM:SS on
DD/MM/YY' is displayed (where 'HH' indicates hours, 'MM' indicates minutes, 'SS'
indicates seconds, 'DD' indicates the day of the month, 'MM' indicates the month of
the year and 'YY' indicates the year). When a transmit path fault exists then a fault
message is displayed instead that indicates the nature of the fault.
2:Traffic
3:Demodulator
5:ABIS
6:Misc
#:1-for-N
9:BUC
Rx:74.0000MHz
2048000bps
4096000sps
7-8