Field Service Ver. 1.0 Jul. 2005
Maintenance
3.
Periodical check
3.1
Service schedule
Guarantee period (5-year or 600,000 prints)
Per cycle
× print number
Upon each call
(60,000)
120,000
Main Unit
200,000
300,000
60,000
DF-601
200,000
PC-103
PC-203
300,000
PC-403
AD-503 60,000
FS-501
300,000
FS-603
3.2
Maintenance items
3.2.1
Parts to be replaced by users (CRU)
No.
Class
1
Imaging Unit C/M/Y
2
Imaging Unit K
3
Dust filter/Cooling Fan
Processing
4
Comb electrode
sections
Toner cartridge: TC
5
(TC Y/TC M/TC C)
Toner cartridge: TC
6
(TC K)
7
Fusing section Deodorant filter
Image Trans-
8
Waste Toner Box
fer section
*1: Also replace the Dust Filter/Cooling Fan packed in the Waste Toner Box at the same
time when the Waste Toner Box is replaced.
*2: Also replace the Deodorant Filter packed in the Toner Cartridge K at the same time
when 20 K is reached.
*3: The parts can be replaced either by User or Customer Engineer.
☞ For details of setting, see "Unit Change" on Page 269 "Adjustment/Setting."
*4: A waste toner full condition is detected with detecting the actual waste toner emissions.
6
12
18
20
●
●
●
●
●
●
●
●
●
●
●
●
Parts to be replaced
When TC K is replaced
× 10,000-print
24
30
36
40
42
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
Cycle
Clean Replace Descriptions
45 K
70 K
30 K
●
12 K
20 K
20 K
(30 K)
3. Periodical check
Number
of times
48
54
●
●
9
●
4
2
1
●
●
9
2
1
●
●
9
1
●
*3
●
*3
●
*1
●
*3
●
*2, 3
●
*2
●
*1, 3, 4