Field Service Ver. 1.0 Jul. 2005
[1]
[3]
11. Perform another test print and check the reference deviation.
12. Repeat the adjustment until the reference line falls within the specified range.
13. Tighten the adjustment screw.
8. Press the Drawer Release button [1]
and then slide out the drawer [2]
from the Paper Feed Cabinet.
[2]
4348fs3510c0
9. Open the Right Door.
[4]
10. Loosen the adjustment screw [3] and
turn screw D [4] to make the adjust-
ment.
NOTE
• Do not damage the passage surface
of the Right Door.
4348fs3511c0
• If width A is greater than the specified
value:
Turn screw D counterclockwise.
4348fs3512c0
• If width A is smaller than the specified
value:
Turn screw D clockwise.
4348fs3513c0
6. Mechanical adjustment