Field Service Ver. 1.0 Jul. 2005
• If adjustment cannot be completed only by inputting numeric value, perform
adjustment according to the following procedure.
11. Perform another test print and check the reference deviation.
12. Repeat the adjustment until the reference line falls within the specified range.
13. Tighten the adjustment screw.
14. Repeat steps 1 to 13 similarly for the Tray 4.
[2]
[1]
4348fs3601c0
[4]
[3]
4348fs3602c0
6. Mechanical adjustment
8. Slide out the drawer [1] and unload
paper from it.
9. Loosen three screws [2] at the center
of the Paper Lifting Plate.
10. Watching the graduations [3] pro-
vided in the drawer, move the Edge
Guide [4] in the rear.
• If width A is greater than the specified
value, move the Edge Guide toward
the front.
• If width A is smaller than the specified
value, move the Edge Guide toward
the rear.