Field Service Ver. 1.0 Jul. 2005
<Binary Division>
Functions
• To set whether to carry out Binary division for data to be transmitted
Use
• Not to carry out Binary division for data to be transmitted
Setting/
• The default setting is ON.
Procedure
<Divided Mail Size>
Functions
• To set the dividing size when carrying out the Binary division for data to be transmit-
ted.
Use
• To change the dividing size of the data.
Setting/
1. Press the Clear key.
Procedure
2. Enter the dividing mail size between 100 and 15000 (in 100 increments) using the
10-Key Pad.
<Connection Timeout>
Functions
• To set the Timeout period for connection in transmitting e-mail to SMTP server.
Use
• To change the timeout period for connection in transmitting e-mail to SMTP server.
Setting/
• Select the timeout period using [+] / [-] keys.
Procedure
• The default setting is 60 sec.
<Server Capacity>
Functions
• To set the Max. capacity per mail which SMTP server can receive.
Use
• To change the Max. capacity per mail which SMTP server can receive.
Setting/
• The default setting is No Limit.
Procedure
<Detail Setting: Port No.>
Functions
• To set the Port number for transmission with SMTP server.
Use
• To enter the port number for transmission with SMTP server.
Setting/
1. Touch [Input].
Procedure
2. Press the Clear key.
3. Enter the port number between 1 and 65535 using the 10-Key Pad.
<Detail Setting: Authentication Setting>
Functions
• To set the Authentication method to logon to SMTP server.
Use
• To change the Authentication method to logon to SMTP server.
Setting/
• The default setting is OFF.
Procedure
• When selecting SMTP Authentication, enter the User ID, the password, and the
Domain name.
"ON"
"60 sec." (30 to 300, in 30 sec. increments)
"No Limit" (1 to 100)
"OFF"
POP Before SMTP
8. Utility Mode
OFF
SMTP Authentication