2. MAIN UNIT REPLACEMENT
(3) Make sure of printing on the labels and print positions.
Print tone
+00 or -10
Judgment criteria of (1): (Horizontal scanning direction)
Distance from the left edge of the label to the left edge of the printed rectangle: [4.5 ± 1 mm]
Judgment criteria of (2): (Vertical scanning direction)
Distance from the top edge of the label to the top edge of the printed rectangle: [8.0 ± 1 mm]
4) Self-Test Result Printing
B-SP2D-GH20-QM
B-SP2D-GH40-QM
(1)
(2)
Batch: 111-11
Strip:
B-SP2D-GH30-QM
2-32
EO18-33014
(Revision Date: Jan. 29, 2004)
2.7 SETTING AND ADJUSTMENT