Svlan Cos Configuration; Svlan Cos Overview; Configuring Svlan Cos - Zte ZXR10 5900E Series User Manual

All gigabit-port intelligent routing switch
Hide thumbs Also See for ZXR10 5900E Series:
Table of Contents

Advertisement

St-
Command
ep
1
ZXR10(config)#
<0-7>],[cos1 <0-7>],[cos2 <0-7>],[cos3
<0-7>],[cos4 <0-7>],[cos5 <0-7>],[cos6
<0-7>],[cos7 <0-7>]
2
ZXR10(config)#
3
ZXR10(config-gei_1/x)#
<session_id>
C h a p t e r
SVLAN COS
Configuration
Table of Contents

SVLAN COS Overview.........................................................23

Configuring SVLAN COS......................................................23

SVLAN COS Configuration Example ......................................24
SVLAN COS Maintenance and Diagnosis................................24
SVLAN COS Overview
In SVLAN QinQ mode, when receiving tagged data packet from
user trunk port, uplink port reserves the original data packet tag
and attaches service provider tag. This tag includes 2 bytes Eth-
ernet type (0x8100) and 2 bytes priority and VID, in which priority
field is 3bits and this field is COS, we call this as service type, ser-
vice level. Or service priority. The function is to configure COS
priority value.
Configuring SVLAN COS
cos-session < session_id >[cos0
interface <port-name>
cos-mode cos-map-session
Confidential and Proprietary Information of ZTE CORPORATION
3
Function
This configures SVLAN COS.
session-id<1 - 16>
This configures a cos one time
or many coses.
This enters interface
configuration mode.
This applies session
corresponding cos to physical
interface.
23

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents