3. SIGNALS AND WIRING

3.9 SSCNET cable connection

(1) SSCNET cable connection
For CN1A connector, connect SSCNET cable connected to controller in host side or servo amplifier.
For CN1B, connect SSCNET cable connected to servo amplifier in lower side.
For CN1B connector of the final axis, put a cap came with servo amplifier.
SSCNET
Controller
(2) How to connect/disconnect cable.
(a) Mounting
1) For SSCNET cable in the shipping status, the tube for protect light code end is put on the end of
connector. Remove this tube.
2) Remove the CN1A CN1B connector cap of servo amplifier.
POINT
Do not see directly the light generated from CN1A CN1B connector of servo
amplifier or the end of SSCNET cable.
When the light gets into eye, may feel something is wrong for eye.
(The light source of SSCNET corresponds to class1 defined in JISC6802 or
IEC60825-1.)
Axis No.1 servo amplifier
SSCNET
cable
CN1A
CN1B
POINT
CN1A CN1B connector is put a cap to protect light device inside connector
from dust.
For this reason, do not remove a cap until just before mounting SSCNET
cable.
Then, when removing SSCNET cable, make sure to put a cap.
Keep the cap for CN1A CN1B connector and the tube for protecting light
code end of SSCNET cable in a plastic bag with a zipper of SSCNET
cable to prevent them from becoming dirty.
When asking repair of servo amplifier for some troubles, make sure to put a
cap on CN1A CN1B connector.
When the connector is not put a cap, the light device may be damaged at the
transit.
In this case, exchange and repair of light device is required.
Axis No.2 servo amplifier
cable
SSCNET
CN1A
CN1B
3 - 26
Final axis servo amplifier
cable
CN1A
Cap
CN1B