Mitsubishi Electric MR-J3-B Instruction Manual page 44

Melservo-j3 series servo amplifier
Hide thumbs Also See for MR-J3-B:
Table of Contents

Advertisement

3. SIGNALS AND WIRING
(2) For 1-phase 230VAC power supply to MR-J3-10B to MR-J3-70B
NFB
1-phase
230VAC
Forced stop
(Note 5)
Note 1. Always connect P
-P
1
2. Always connect P-D. (Factory-wired.) When using the regenerative brake option, refer to Section 11.2.
3. For connection of the servo amplifier and servo motor, use of the option cable is recommended. Refer to Section 11.1 for
selection of the cable.
4. If deactivating output of trouble (ALM) with parameter change, configure up the power supply circuit which switches off the
magnetic contactor after detection of alarm occurrence on the controller side.
5. For the sink I/O interface. For the source I/O interface, refer to Section 3.7.3.
(Note4)
Controller
Alarm
forced stop
RA1
RA2
MC
(Note 1)
(Note 2)
. (Factory-wired.) When using the power factor improving DC reactor, refer to Section 11.10.
2
Forced
ON
OFF
stop
MC
Servo amplifier
CNP1
L
1
CNP3
(Note 3)
L
U
2
L
V
3
N
W
P
1
P
2
PE
CNP2
P
C
D
CN2
Encoder cable
L
11
L
21
CN3
CN3
EM1
DOCOM
DOCOM
DICOM
ALM
3 - 3
MC
SK
Servo motor
U
2
Motor
V
3
M
W
4
1
(Note 3)
Encoder
24VDC
RA1
Trouble
(Note 4)
(Note 5)