Advertisement

5. PARAMETERS
No.
Symbol
PC12
MO2
Analog monitor 2 offset
Used to set the offset voltage of the analog monitor2 (MO2) output.
PC13
For manufacturer setting
Do not change this value by any means.
PC14
PC15
PC16
PC17 **COP4 Function Selection C-4
Home position setting condition in the absolute position detection system can be
selected.
0 0 0
PC18
For manufacturer setting
Do not change this value by any means.
PC19
PC20
PC21 *BPS
Alarm history clear
Used to clear the alarm history.
0 0 0
PC22
For manufacturer setting
Do not change this value by any means.
PC23
PC24
PC25
PC26
PC27
PC28
PC29
PC30
PC31
PC32
Name and Function
Selection of home position setting condition
0: Need to pass motor Z phase after the power
supply is switched on.
1: Not need to pass motor Z phase after the power
supply is switched on.
Alarm history clear
0: Invalid
1: Valid
When alarm history clear is made valid, the alarm
history is cleared at next power-on.
After the alarm history is cleared, the setting is
automatically made invalid (reset to 0).
5 - 20
Initial
Setting
Unit
Value
Range
0
mV
-999
to
999
0
0
0
0000h
0000h
Refer to
Name
and
function
column.
0000h
0000h
0000h
0000h
Refer to
Name
and
function
column.
0000h
0000h
0000h
0000h
0000h
0000h
0000h
0000h
0000h
0000h
0000h