11. OPTIONS AND AUXILIARY EQUIPMENT
(b) Surge suppressor
The recommended surge suppressor for installation to an AC relay, AC valve, AC electromagnetic
brake or the like near the servo amplifier is shown below. Use this product or equivalent.
Surge suppressor
Surge suppressor
Rated
voltage
C [ F]
R [Ω]
AC[V]
50
200
0.5
(1W)
Note that a diode should be installed to a DC relay, DC valve or
the like.
Maximum voltage: Not less than 4 times the drive voltage of the
Maximum current: Not less than twice the drive current of the
(c) Cable clamp fitting AERSBAN
Generally, the earth of the shielded cable may only be connected to the connector's SD terminal.
However, the effect can be increased by directly connecting the cable to an earth plate as shown below.
Install the earth plate near the servo amplifier for the encoder cable. Peel part of the cable sheath to
expose the external conductor, and press that part against the earth plate with the cable clamp. If the
cable is thin, clamp several cables in a bunch.
The clamp comes as a set with the earth plate.
Strip the cable sheath of
the clamped area.
MC
Relay
This distance should be short
(within 20cm).
Test voltage AC[V]
Across
T-C 1000(1 to 5s)
relay or the like
relay or the like
-SET
cutter
cable
Surge suppressor
(Ex.) 972A.2003 50411
(Matsuo Electric Co.,Ltd. 200VAC rating)
Outline drawing [Unit: mm]
Vinyl sheath
Blue vinyl cord
10 or less
10 3
15 1
200 or more
48 1.5
Clamp section diagram
11 - 45
Red vinyl cord
10 or less
10 3
200 or more
RA
Diode
Cable
Cable clamp
(A,B)
External conductor
18 1.5
6
4
31
Earth plate