5. PARAMETERS
(1) For output pulse designation
Set "
0
" (initial value) in parameter No. PC03.
Set the number of pulses per servo motor revolution.
Output pulse
set value [pulses/rev]
For instance, set "5600" to Parameter No. pa15, the actually output A/B-phase pulses are as indicated
below:
A B-phase output pulses
(2) For output division ratio setting
Set "
1
" in parameter No. PC03.
The number of pulses per servo motor revolution is divided by the set value.
Resolution per servo motor revolution
Output pulse
For instance, set "8" to Parameter No. pa15, the actually output A/B-phase pulses are as indicated
below:
A B-phase output pulses
5600
1400[pulse]
4
Set value
262144
1
8192[pulse]
8
4
5 - 8
[pulses/rev]