Mitsubishi Electric MR-J3-B Instruction Manual page 11

Melservo-j3 series servo amplifier
Hide thumbs Also See for MR-J3-B:
Table of Contents

Advertisement

CONFORMANCE WITH UL/C-UL STANDARD
(1) Servo amplifiers and servo motors used
Use the servo amplifiers and servo motors which comply with the standard model.
Servo amplifier
:MR-J3-10B to MR-J3-700B
MR-J3-10B1 to MR-J3-40B1
Servo motor
:HF-MP
HF-KP
HF-SP
(2) Installation
Install a fan of 100CFM (2.8m
at least equivalent capability.
(3) Short circuit rating
This servo amplifier conforms to the circuit whose peak current is limited to 5000A or less. Having been
subjected to the short-circuit tests of the UL in the alternating-current circuit, the servo amplifier conforms to
the above circuit.
(4) Capacitor discharge time
The capacitor discharge time is as listed below. To ensure safety, do not touch the charging section for 15
minutes after power-off.
Servo amplifier
MR-J3-10B 20B
MR-J3-40B 60B 10B1 20B1
MR-J3-70B
MR-J3-40B1
MR-J3-100B
MR-J3-200B 350B
MR-J3-500B 700B
(5) Options and auxiliary equipment
Use UL/C-UL standard-compliant products.
This servo amplifier is UL/C-UL-listed when using the fuses indicated in the following table. When the servo
amplifier must comply with the UL/C-UL Standard, be sure to use these fuses.
Servo amplifier
MR-J3-10B (1) 20B
MR-J3-40B 20B1
MR-J3-60B to 100B 40B1
MR-J3-200B
MR-J3-350B
MR-J3-500B
MR-J3-700B
3
/min) air flow 4 in (10.16 cm) above the servo amplifier or provide cooling of
Discharge time
[min]
1
2
3
4
5
9
10
Fuse
Class
Current [A]
T
A - 10
Voltage [V]
10
15
20
40
AC250
70
125
150

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents