Tainet T-288C User Manual page 90

Network series
Table of Contents

Advertisement

INSTRUCTION SETS
Cmd
&Xn
transmit clock source 0:interal 1:exteral 2:loopback
&Yn
recall user profile n 0n power up , n=0-9
&Zn=x store phone number x to memory location n, n=0-9
\ An
MNP max block size 0:64 1:128 2:192 3:256 bytes
\ Bn
disconnect send break Sequence 0:no 1:yes
\ Gn
DCE-DCE flow control 0:disable 1:enable
\ Hn
ENQ/ACK 0:none 1:to host 2:to peripheral
\ Jn
speed conversion 0:On 1:Off
\ Kn
break option 0:expedited destructive 1:expedited nondestructive
2:queued
\ Nn
data transfer mode 0:direct 1:normal 2:auto-reliable
3:reliable
\ Qn
flow control 0:none 1:XON/XOFF 2:RTS/CTS 3:CTS
\ R
remote access command
\ Xn
Xon/Xoff pass through 0: Off 1: On
%An
async tolerance 0:-2.5% ... 1% 1:-2.5% ... 2.3%
%Cn
data compression 0:off 1:on
%Dn
DTR control 0:normal (108/2)
%En
auto retrain 0:off 1:on
Table 5-1: AT Command Set (cont.)
Function Description
1:DTR on auto dial/answer (108/1)