2.2.2 Attaching the reform H unit
Note:
After mounting the reform H unit, be sure to check the rel-
evant item referring to "2.3 Check details after mounting
separately sold parts".
(1) Insert the reform H unit, and fix it with a screw.
(2) Fix the bracket with an attaching screw.
(3) Remove the dummy connector connected to the CN3 on
the MAIN Board. (Only when attaching the reform H unit)
MAIN
Board
CN3
(4) Guide the wires from the reform H unit through the wire
clamps as shown in the drawing, and then connect the
wires to the MAIN Board.
As the reform H unit moves up and down during operation,
be sure to allow about 1 to 2 cm wire slack.
Reform H unit
* When attaching the reform H unit,
be careful not to damage the heat
roller with the bracket.
Bracket
Screw :
QYSDST3006NA
Screw :
QYSDST3006NA
Insert the tip of the
shaft into the front
plate.
Dummy
connector
Wire clamp
MAIN Board
CN3
CN2
2.2.3 Attaching the IC contact unit
Note:
After mounting the IC contact unit, be sure to check the
relevant item referring to "2.3 Check details after mount-
ing separately sold parts".
(1) Remove the screw attaching the turn unit from the front
side of the main unit.
(2) Remove the wires, which come from the turn unit, from the
wire clamp.
(3) Remove the three screws attaching the turn unit, and then
pull out the turn unit. (Only the models with turn unit)
Turn unit
Screw :
QYSDST3006NA x 3
Screw :
QYSDST3006NA
Wire clamp
(No.HD007<Rev.001>)1-7