2.3.1 IC contact position adjustment
Apply a contact label (part number: KXL46372-001) on the IC
chip of a contact IC card.
Select the IC contact test from "off line test" in the service mode
to perform the test.
After the test, measure the IC contact position mark on the con-
tact label using a vernier caliper to check if the position stays
within the specs.
If the position does not stay within the specs, correct the position
in the "OffsetContact" mode in the service mode.
When the position is corrected, turn off the power and turn it on
again before testing the IC contact.
(Specs)
IC contact
position specs
direction
direction
a
b
Contact label
(part number:KXL46372-001)
c
d
e
f
a : 10.25 ~ 12.25 mm
b : 17.87 ~ 19.87 mm
c : 19.23 ~ 20.93 mm
d : 21.77 ~ 23.47 mm
e : 24.31 ~ 26.01 mm
f : 26.85 ~ 28.55 mm
(No.HD007<Rev.001>)1-13