Mechanical Troubleshooting - SCIFIT STEP ONE Service Manual

Recumbent stepper
Hide thumbs Also See for STEP ONE:
Table of Contents

Advertisement

Symptom:
1. Clunking noise and rod end links seem to be loose.
2. Squeaking at high resistance coming from belts.
3. Indexing handle spins 360 degrees and does not stop at +/- 30 degrees.
1. Clunking noise and rod end links seem to be loose.
a. Torque all link bolts to 720 in/lbs (60 ft/lbs).
2. Squeaking at high resistance coming from belts.
a
. C lean pedal belt pulleys a nd pe dal belts of a ny oi l. This c an a lso
be done if the pedal seems to be slipping on the way down.
3. Indexing handle spins 360 degrees and does not stop at +/- 30 degrees.
a. Adjust the set screw on the outer handle up one revolution.
SCIFIT
Scientific Solutions For Fitness
SPECIFICATIONS

MEChANICAL TROUBLEShOOTINg

Step One Mechanical Troubleshooting