ELECTRICAL PARTS REMOVAL/REPLACEMENT
Step 3:
Use a phillips screwdriver to remove
the four M5 x 12mm screws (#91218),
securing the console bracket (#A5044) to
the console, then remove the bracket.
conSoLE AnD conSoLE BrAckET rEpLAcEmEnT
Repeat steps 1 thru 3, but in reverse.
Step 1:
Remove the console and lower/upper covers according to the "Lower/Upper Cover Removal" process.
Step 2:
The mid-step counter cable (#A5409)
is hidden within a frame channel on the
upper part of the main frame behind the
brake, carefully pull out the cable to
access the housing connection between the
mid-cable and the magnet cable (#A5410).
SCIFIT
Scientific Solutions For Fitness
SPECIFICATIONS
SPECIFICATIONS
SPECIFICATIONS
mID-cABLE rEmovAL
66
SCIFIT
Frame channel
Magnet Cable
Mid-Cable
Scientific Solutions For Fitness