SPECIFICATIONS
MEChANICAL PARTS REMOVAL/REPLACEMENT
Step 2:
Position the the brake, so the mounting
studs are approximately 1/4" from the end
of the brake's slot opening (See drawing).
1/4"
from
the end
Step 3:
Loosely place the four 1/4"-20 nylock
nuts (#1137018) and four M6 flat washers
(#1140355) onto the mounting studs.
Step 4:
Use a 7/16 socket to secure the four
1/4"-20 nylock nuts and four M6 flat
washers to the brake.
7/16 Socket