MEChANICAL PARTS REMOVAL/REPLACEMENT
Tools Required: * 1/4" Allen Hex * Ratchet * 3/8" Allen Hex * 5/8" Wrench
* Torque wrench with range above 720 in/lbs * 5/8" Socket
Step 1:
Loosely attach the new pivot link to the
pivot blade with the hardware previously
removed as shown in the diagram.
Note: Verify the washers are placed in
the correct location.
Step 2:
Align the assembly link and the pivot
link with the bottom holes of the outer
handle and loosely secure them with
the h ardware pr eviously r emoved.
Note: Verify the washers are placed in
the correct location.
SCIFIT
Scientific Solutions For Fitness
SPECIFICATIONS
SPECIFICATIONS
LEFT pIvoT LInk rEpLAcEmEnT
Washer between
the pivot blade
and the screw
Washer between
the pivot blade
and the Pivot link
Outside the
pivot link
Between the
pivot link and
lower outer
handle assembly
23
SCIFIT
Scientific Solutions For Fitness
Assembly
link
SCIFIT