Example of the E-mail sent for an error
The following E-mail is sent when an error has occurred.
=== Panasonic projector report(CONFIGURE) ===
Projector Type
Serial No
----- check system -----
MAIN CPU BUS
FAN
INTAKE AIR TEMPERATURE
OPTICS MODULE TEMPERATURE [ OK ]
AROUND LAMP TEMPERATURE
LAMP1 REMAIN TIME
LAMP2 REMAIN TIME
LAMP1 STATUS
LAMP2 STATUS
SHUTTER
INTAKE AIR TEMP.SENSOR
OPTICS MODULE TEMP.SENSOR
AROUND LAMP TEMP.SENSOR
BATTERY
COLOR WHEEL
COVER OPEN
FILTER UNIT
AIR FILTER
(Error code 04 00 00 00 00 00 00 00)
Intake air temperature
Optics module temperature : 39 degC / 102 degF
Around lamp temperature
PROJECTOR RUNTIME
POWER ON
LAMP1 ON
LAMP1 ECO
LAMP1 NORMAL
LAMP1 REMAIN
LAMP2 ON
LAMP2 ECO
LAMP2 NORMAL
LAMP2 REMAIN
-------- Current status ---------
MAIN VERSION
NETWORK VERSION
SUB VERSION
LAMP STATUS
INPUT SIGNAL
REMOTE2 STATUS
----- Wired Network configuration -----
DHCP Client OFF
IP address 192.168.10.100
MAC address 70:58:12:00:00:00
Wed Jan 18 11:42:37 2012
----- Memo -----
User name [Change password] page
Click [Change password].
1
[Administrator]
Used to change the setting of the [Administrator].
2
[User]
Used to change the setting of the [User].
3
[Next]
Used to change the setting of the password.
104 - ENGLISH
Chapter 4 Settings — [NETWORK] menu
: DW740
: SH1234567
[ OK ]
[ OK ]
[ OK ]
[ OK ]
[ OK ]
[ OK ]
[ OK ]
[ OK ]
[ OK ]
[ OK ]
[ OK ]
[ OK ]
[ OK ]
[ OK ]
[ OK ]
[ FAILED ]
[ OK ]
: 26 degC / 78 degF
: 30 degC / 86 degF
1 H
1 times
1 times
0 H
0 H
1999 H
1 times
0 H
1 H
1999 H
1.00
1.00
1.00
LAMP1=ON LAMP2=ON
RGB1 ---
0.00kHz / 0.00Hz
DISABLE