GS1 Composite Code Message Length
Scan the bar codes below to change the message length. Refer to
Message Length Description
mum and Maximum lengths = 1-2435. Minimum Default = 1, Maximum
Default = 2435.
Minimum Message Length

GS1 Emulation

The scanner can automatically format the output from any GS1 data carrier to
emulate what would be encoded in an equivalent GS1-128 or GS1 DataBar
symbol. GS1 data carriers include UPC-A and UPC-E, EAN-13 and EAN-8,
ITF-14, GS1-128, and GS1-128 DataBar and GS1 Composites. (Any applica-
tion that accepts GS1 data can be simplified since it only needs to recognize
one data carrier type.)
If GS1-128 Emulation is scanned, all retail codes (U.P.C., UPC-E, EAN8,
EAN13) are expanded out to 16 digits. If the AIM ID is enabled, the value will be
the GS1-128 AIM ID, ]C1 (see
If GS1 DataBar Emulation is scanned, all retail codes (U.P.C., UPC-E, EAN8,
EAN13) are expanded out to 16 digits. If the AIM ID is enabled, the value will be
the GS1-DataBar AIM ID, ]em (see
If GS1 Code Expansion Off is scanned, retail code expansion is disabled, and
UPC-E expansion is controlled by the
the AIM ID is enabled, the value will be the GS1-128 AIM ID, ]C1 (see
Symbology Charts
If EAN8 to EAN13 Conversion is scanned, all EAN8 bar codes are converted
to EAN13 format.
(page 7-2) for additional information. Mini-
Symbology Charts
Symbology Charts
on page A-1).
Maximum Message Length
on page A-1).
on page A-1).
UPC-E0 Expand
(page 7-29) setting. If