Rs232 Receiver Time-Out; Rs232 Handshaking - Honeywell Vuquest 3310g User Manual

Area-imaging scanner
Hide thumbs Also See for Vuquest 3310g:
Table of Contents

Advertisement

7 Data, 1 Stop, Parity Mark
8 Data, 1 Stop, Parity Mark

RS232 Receiver Time-Out

The unit stays awake to receive data until the RS232 Receiver Time-Out
expires. A manual or serial trigger resets the time-out. When an RS232
receiver is sleeping, a character may be sent to wake up the receiver and
reset the time-out. A transaction on the CTS line will also wake up the
receiver. The receiver takes 300 milliseconds to completely come up.
Change the RS232 receiver time-out by scanning the bar code below, then
scanning digits from the inside back cover of this manual, then scanning
Save. The range is 0 to 300 seconds. Default = 0 seconds (no time-out -
always on).

RS232 Handshaking

RS232 Handshaking allows control of data transmission from the scanner
using software commands from the host device.
turned Off, no data flow control is used.
Flow Control, No Timeout: The scanner asserts RTS when it has data to
send, and will wait indefinitely for CTS to be asserted by the host.
Two-Direction Flow Control: The scanner asserts RTS when it is OK for
the host to transmit. The host asserts CTS when it is OK for the device to
transmit.
RS232 Receiver Time-Out
7 Data, 2 Stop, Parity Mark
When RTS/CTS is
2 - 23