Technoarc Menu Map - High End Systems TechnoArc User Manual

Table of Contents

Advertisement

TechnoArc Menu Map

Menu
Level 2
Address
Set DMX: ###
Time Info.
Info
Value Display
Head Temp
Software Ver
Lamp On/Off
Lamp On/Pwr
Lamp On/DMX
Lamp
Lamp Off/DMX
Lamp On Temp
Lamp Off Temp
TechnoArc
User Manual
TM
Level 3
Option/Setting
1-474
Current Time
####h
Ttl Life Hrs
####h
Last Run Hrs
####h
Lamp Hrs
####h
LampOff Time
####min
Timer PIN
XXX
Clr Last Run
L-Timer PIN
XXX
Clr Lamp Time
Pan
. . .
XXX
Indigo Dim
XXX°C/°F
VerX.XXXX
On
Off
On
Off
On
Off
On
Off
CHAPTER 3
Menu System
Description/Notes
Sets the first value of a unique
21channel range on DMX link.
Power On running time in hours
Fixture running time in hours
Lamp running time in hours
Total Lamp hours
Lamp off time in minutes
Sets a Timer Password
Resets last run time to 0
Lamp Password Code = "038"
Reset lamp time to 0
Displays parameter's current
DMX value
Displays head temperature in
celsius and Farienheit
Displays sofware version
Manually turns lamp On/Off
Lamp On/Off when Power On
Lamp on via DMX
Lamp Off via DMX
Displays temperature for lamp
restart in Fahrenheit or Celsius
(see
in
Temp. C/F 
Set 
Displays temperature to turn lamp
off in Fahrenheit or Celsius (see
in
menu)
Temp. C/F 
Set 
menu)
19