Linking TechnoArc Fixtures

The TechnoArc fixture operates on standard DMX512 link controlled by a DMX console. The
number of fixtures on a link will be determined by the combined number of channels required by
all the fixtures. A TechnoArc fixture requires a 21 channel footprint on a standard DMX512 link.
Attach the fixture to the link using data-grade cable and 5-pin or 3-pin XLR cable connectors.

Cable Connectors

The TechnoArc fixture accepts both 3-pin and 5-pin XLR cable connectors. Cabling must have a
male XLR connector on one end of the cable and a female XLR connector on the other end.
Note:
Pins four and five of a 5-pin cable connector are not used, but they
allow a secondary data link to pass through the fixture.
grounding lug
(inside XLR shell)
common
(cable shield)
Common
(cable shield)
1
2
negative
3
(data
complement)
positive
(data true)
Male XLR Connector
*This data line is not used by the fixture, but allows data to pass through the fixture.
12
XLR Shell
1
2
negative
3
positive
Grounding lug (inside XLR shell)
5
positive
4
(data true)*
negative
(data complement)*
grounding lug
(inside XLR shell)
2
1
common
3
(cable shield)
XLR shell
positive
(data true)*
negative
(data
complement)*
positive
(data true)
Female XLR Connector
Common
5
1
4
2
(cable shield)
3
negative
(data
complement)
TechnoArc
User Manual
TM

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents