Mantels and surrounds - inbuilt models only
Combustible mantels and surrounds require clearance from the unit to minimise
fire danger. Mantels and surrounds, made of combustible materials such as wood,
are allowed providing they are outside the minimum clearances shown.
The Neo gas fireplace is not designed to be built into bookcases.
A Mantel needs to be a minimum of 400 mm away from the edge of the inner glass.
B
Maximum mantel depth at 400 mm (A) is 250 mm.
C
Surround needs to be a minimum of 400 mm away from the edge of the inner glass.
For every 50 mm of added mantel depth there must be an additional 100 mm of clearance from
the edge of the glass.
For example:
M
antel depth
300 mm
350 mm
400 mm
8 | Neo operation guide: 11907-E 05-14
C
A:
clearance required
500 mm
600 mm
700 mm
A
B