Mantels, surrounds, and hearths

B - Mantel depth
Min
D - Surround
projection
C - Surround from side of fireplace
A mantel and surround are allowed providing they are outside the minimum clearances shown
below.
A
Mantel height from top of fireplace
B
Mantel depth at 400 mm (vertical clearance)
For every 50 mm of added mantel depth, there must be an additional 100 mm of vertical clearance. For
example; a mantel depth (B) of 350 mm will require 500 mm (A) of vertical clearance.
C
Surround from side of fireplace
D
Surround projection at 300 mm (side clearance)
For every 50 mm of added surround projection, there must be an additional 50 mm of side clearance. For ex-
ample; a surround projection (D) of 100 mm will require 350 mm (C) of side clearance.
Hearths
A hearth is not necessary but can be used for decorative purposes or protection of sensitive
flooring if required. It must not obscure the front of the fire.
Rinnai new Zealand
Minimum Vertical Clearance 400mm
A - Mantel height from top of fireplace
400 mm minimum
300 mm maximum
300 mm minimum
50 mm maximum
8