Replacing A Fan; Replacing A Power Supply - IBM TotalStorage DS4100 Installation, User's, And Maintenance Manual

Ibm switch users and maintenance guide
Hide thumbs Also See for TotalStorage DS4100:
Table of Contents

Advertisement

Lever
Pull ring
Figure 19. Replacing a power supply
2. Close the lever until the pull-ring latch locks in place. Make sure that the lever
locks into place in the storage server chassis. Then gently push the front of the
power supply to ensure that it is fully seated.
3. For the DS4100 base storage server, repeat step 1 and step 2 to replace the
second power supply.

Replacing a fan

Complete the following steps to replace the fan units that you removed before the
installation:
1. Place the fan in front of the fan bay.
2. Ensure that you move the fan latch in the same direction as the arrow before
you slide the fan all the way into the bay. If the fan does not go into the bay,
rotate it 180° (see Figure 20).
Figure 20. Replacing a fan
Chapter 2. Installing the storage server
31