Back View Of Ds4100 Base Storage Server; Back View Of Ds4100 Single-Controller Storage Server - IBM TotalStorage DS4100 Installation, User's, And Maintenance Manual

Ibm switch users and maintenance guide
Hide thumbs Also See for TotalStorage DS4100:
Table of Contents

Advertisement

Figure 4. Back view of DS4100 base storage server
Figure 5 shows the components at the back of the DS4100 single-controller storage
server. The DS4100 single-controller storage server has a controller blank instead
of a second RAID controller and a power supply blank instead of a second power
supply.
Figure 5. Back view of DS4100 single-controller storage server
RAID controller
Hot-swap fans
10
IBM TotalStorage DS4100 Storage Server: Installation, User's, and Maintenance Guide
Hot-swap fan bays
Raid controllers
Hot-swap
power supplies
Hot-swap fan bays
RAID controller
Power supply
Each RAID controller contains three ports for Small Form-Factor Pluggable
(SFP) modules that connect to the fibre channel cables. Two of the SFP
ports (labelled Host 1 and Host 2) are for host server attachment. The third
SFP port (labelled Expansion) is used to connect additional expansion units
to the storage server.
Note: In the DS4100 single-controller storage server, the third SFP port
(labelled Expansion) is present but not active.
Each RAID controller also contains a battery to maintain cache data in the
event of a power failure. For more information, see "Cache memory and
RAID controller battery" on page 75.
Attention: You will lose access to data if you attempt to hot-swap the RAID
controller in a DS4100 single-controller storage server.
The storage server has two interchangeable hot-swap and redundant fan
CRUs. Each fan CRU contains two fans. If one fan CRU fails, the second

Advertisement

Table of Contents
loading

Table of Contents