Installing The Ds4000 Storage Manager Client; Redundant Ac Power Connections To Controllers And Drive Expansion Units - IBM TotalStorage DS4100 Installation, User's, And Maintenance Manual

Ibm switch users and maintenance guide
Hide thumbs Also See for TotalStorage DS4100:
Table of Contents

Advertisement

Rack power cable connector
Figure 56. Redundant AC power connections to controllers and drive expansion units
6. Go to "Turning the storage server on and off" on page 65 for the initial startup of

Installing the DS4000 Storage Manager client

Refer to the IBM TotalStorage DS4000 Storage Manager 9.10 Installation and
Support Guide for the appropriate operating system for instructions on how to install
the Storage Manager software. Use that document and the online help to configure
the logical drives, partitions, and so on for the RAID controllers. Use your operating
62
IBM TotalStorage DS4100 Storage Server: Installation, User's, and Maintenance Guide
one-half of the current load. If there is only one power supply unit, it will
handle all of the current load. To ensure maximum protection against
power loss due to power supply unit failure or a power circuit tripping,
both power supply units must be connected and powered on. See
Table 10 on page 15 for the DS4100 AC power requirements.
See Figure 56 for an example of redundant power cabling.
Exception: The DS4100 single-controller storage server has only one
power supply, so it does not support power redundancy.
Rack power cable
AC distribution unit
power cord
For details about power requirements, see "DS4100 specifications" on
page 14.
the storage server.
Attention:
Before you power on the storage server, any storage expansion
units should be completely connected to the storage server.
Drive expansion unit
power supplies
Controller power supplies
AC distribution units

Advertisement

Table of Contents
loading

Table of Contents