Faults: Causes And Cures; Fault-Finding Procedures; Trouble-Shooting Guide - Norton CST 65 Modulo Operating Instructions Manual

Table of Contents

Advertisement

7

Faults: causes and cures

7.1

Fault-finding procedures

Should any fault occur during the use of the machine, turn it off, and isolate it from the electrical
supply. Any works dealing with the electrical system or supply of the machine can only be carried
out by a qualified electrician.
7.2

Trouble-shooting guide

Trouble
Motor is not running
Motor stops during the cutting,
but can be restarted after a
short period (overload
protection)
No water on the blade
18
Possible source
No electricity
Connection cable section too
small
Defective connection cable
Defective switch
Defective motor
Cutting advance too quick
Blade is blunt or glazed
Defective blade
Wrong blade specification for
the application
Water pump switched off
Not enough water in the pan
Water tap is closed
Water supply system is blocked
up
Water pump is not working
Resolution
Check the electrical supply
(fuse for example)
Change connection cable
Change connection cable
CAUTION : can only be solved
by qualified electrician
Change motor or contact motor
manufacturer
Cut slowly
Sharpen the blade in
calcareous stone
Change blade
Change blade
Switch on the water pump
Refill the water pan
Open tap on blade guard
Clean water supply system
Change the pump

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cst 85 moduloCst 100 modulo

Table of Contents