Christie 35/70 Maintenance And Service Manual page 21

Automated electronic film projector
Table of Contents

Advertisement

E
:
NTRY
C
:
ODE
A
CTION
:
S
S
:
TATUS
C A : T h e R E A D Y C o m m a n d [ O P ]
This operational command initiates the READY sequence.
When the projector is in READY mode, if the <READY> key is pressed again, the LED
display strip displays the reel counter. To return the show counter to the display, enter
a G1 (DISPLAY COUNTER) command.
E
:
NTRY
C
:
ODE
A
CTION
:
S
S
:
TATUS
C B : T h e N O T R E A D Y C o m m a n d [ O P ]
This operational command places the system in a NOT READY state. When in this state, the projector will not
accept any commands that require film motion.
E
:
NTRY
C
:
ODE
A
CTION
:
S
S
:
TATUS
CHRISTIE INC. - 35/70 Service/PM Manual
July, 1997
<CMD-C>, <9>
C9
Reset the frame counter.
Unchanged.
<READY>
CA
1. Apply power to motor systems.
2. Check all limit switches.
3. Check the CV, Pulldown, and Shutter motor systems.
4. Set loop.
5. Execute single frame advance and stop.
Set to 0.
<NOT RDY>
CB
1. Remove power from motor systems.
2. Reinitialize software values and turns the AUTO DOUSER
command off .
3. Reset LED error indicators.
Set to B.
2 . G e n e r a l D e s c r i p t i o n