Christie 35/70 Maintenance And Service Manual page 19

Automated electronic film projector
Table of Contents

Advertisement

E
:
NTRY
C
:
ODE
A
CTION
:
S
S
:
TATUS
Table 2.5 illustrates the sequence of commands necessary for auto-logging. In this example, the number of
shows is equal to five, and the first show to be shown after all cues have been logged is Show #2.
Command
(Load the film on the reel so
that the BOF tape for Show #1
is above the gate or on the
supply reel.)
READY
SET MAX SHOWS = 5
SET NEXT SHOW = 1
SET CURRENT SHOW = 1
CUE
AUTO LOG
SET NEXT SHOW
CUE
CHRISTIE INC. - 35/70 Service/PM Manual
July, 1997
<CMD-C>, <6>
C6
Projector logs all BOF and EOF sensor tapes on the reel.
Unchanged.
Input
<READY>
<H> , <D> ,
<5>
<H> , <8> ,
<1>
<H> , <5> ,
<1>
<CUE>
<C> , <6>
<H> , <8> ,
<2>
<CUE>
Table 2.5: Command Sequence for Auto Logging
2 . G e n e r a l D e s c r i p t i o n
Result
Puts projector into
READY mode.
Sets number of shows
to 5.
Sets Show #1 as next
show.
Sets current show to 1.
Projector cues on BOF
of Show #1.
Projector logs all BOF
and EOF tapes on the
reel.
Sets Show #2 as next
show.
Projector cues on BOF
of Show #2.
Reference
Chapter 3
Section 0
Section 0
Section 0
Section 0
Section 0
Section 0
Section 0
Section 0

Advertisement

Table of Contents
loading