Note: If you should hear a sucking sound, you may have a leak on the inlet side of the fresh
water tank. There are 2 hoses connected to the top of the tank. The larger diameter hose is the
water fill hose and the smaller diameter hose is the water vent hose. Inspect the hoses for leaks
and make certain that the hose connections are secure.
Cockpit Shower – Cold)
The cockpit shower located below the transom sink and is covered with a white cap.
This fresh water faucet/nozzle can also be used at the transom sink.
First, depress the fresh water switch located on the switch panel to the forward
position to activate the fresh water pump. Then, pull open the cap and pull out the
shower nozzle and hose. Press the button on the nozzle to begin spraying.
See the section titled Fresh Water Pump for operating instructions before using this
shower.

Head Waste System

WHAT IS THE LAW?

a wide spectrum of water pollution problems, including marine sewage from boats in navigable U.S. waters
including coastal waters up to three miles offshore. The law further provides for "no discharge" by boats operated
in enclosed lakes and reservoirs or in rivers not capable of interstate navigation. States may apply to the EPA to
have certain other waters declared "no discharge zones" if discharge of treated sewage would be harmful. In
short, boats with installed toilets must have an operable Coast Guard approved Marine Sanitation Device (MSD)
designed to either hold sewage for pump out ashore or for discharge in the ocean beyond the three mile limit, or
to treat the sewage to Federal standards prior to discharge.
All boats built since 1977 with installed toilets must have an operable approved type I, II or III MSD. Since 1980,
all boats (including those built before 1977) with installed toilets must have an operable MSD. Both the U.S.
Coast Guard and the Natural Resources Police can enforce MSD requirements.
Check with your local authorities, Coast Guard, local marina or your dealer for the rules and/or laws that may
apply specifically in your area.

Center Console with Enclosed Head (Porta-Potti)

This porta-potti comes equipped with a 2.8-gallon holding tank. To operate the porta-potti system:
Set the portable toilet on its front side so the cap on the holding tank is in a vertical position.
Remove the cap and add SeaLand brand holding tank deodorant following the instructions on the
deodorant container. Replace the cap firmly.
Before using: Set the portable toilet in the upright position and remove the cap located on the
right rear side of the fresh water tank. Fill with fresh water just below the neck of the fresh water
inlet. Depress the bellows pump to add water to the bowl.
After using: To flush, open slide valve by pulling out the handle and press the bellows pump one
or more times. After flushing, close slide valve by pushing handle.
Caution: Never add holding tank deodorant to the waste holding tank by pouring directly into the
toilet bowl.
Before operating the porta-potti head system, refer to the manual in your owner's packet supplied by the porta-
potti manufacturer for specific operating instructions.
Head – Porta-Potti with Dockside Discharge (Optional)
This optional head system includes the same porta-potti as the one described above but it has a 5.2-gallon
holding tank. Be sure to follow the same operating instructions as shown above.
To utilize the optional dockside discharge feature, first locate the waste outlet. It is a stainless steel fitting, labeled
waste and it is located amidships on the port gunwale. Twist the waste outlet cap to open the fitting and insert the
Congress enacted the Clean Water Act of 1972 (amended in 1987). This law addresses