Table 9
Switch data window entries (continued)
Entry
Zoning Default Visibility
Default Zone
Discard Inactive
Temperature
Security Auto Save
Security Fabric Binding
Enable
Fan 1 Status
Fan 2 Status
Power Supply 1 Status
Power Supply 2 Status
Beacon Status
Broadcast Support
In-band Enabled
Temperature Failure Port
Shutdown
Warning Temperature
Failure Temperature
NTP Client Enabled
70
Managing switches
Description
Zoning visibility status. Permits (All) or prevents (None)
communication between attached devices in the absence of
an active zone set.
The Default Zone parameter enables (True) or disables
(False) communication among ports/devices that are not
defined in the active zone set or when there is no active
zone set. This parameter must have the same value
throughout the fabric. If interop mode is McDATA Fabric
Mode, the Default Zone parameter is automatically
distributed throughout the fabric. If McDATA 4Gb SAN
Switches are in a fabric with other M-Series directors and
edge switches, and the interop mode is Standard/Open
Fabric, the Default Zone parameter MUST be disabled
(False) on the McDATA 4Gb SAN Switches for zoning to
function properly.
Automatically removes the previously active zone set when a
zoneset is activated on a switch
Internal switch temperature °C
If enabled (default), the security configuration is saved to
non-volatile memory on the switch. If disabled, the security
file is saved only to temporary memory. The Auto Save
feature is used when Fabric Binding is enabled. When Auto
Save is disabled, any updates from remote switches will not
be saved locally. If the local switch is reset, it may isolate.
If enabled, the expected domain ID of a switch is required
before attaching to the fabric
Not applicable
Not applicable
Power supply 1 status
Not applicable
Beacon status. Switch LEDs are blinking (on) or not (off).
Broadcast support status. Broadcast support is enabled or
disabled (default).
In-band management status. Permits (True) or prevents
(False) a switch from being managed over a FC port.
Non-configurable (always enabled for this switch). All ports
are downed when the switch temperature exceeds the
Failure Temperature.
Non-configurable temperature threshold (65° Celsius) above
which a warning condition alarm is generated.
Non-configurable temperature threshold (70° Celsius) above
which a failure condition alarm is generated.
Enabled or disabled. Allows for switches to synchronize their
time a centralized server.