Table 2. Abbreviated list of firmware error codes (continued)
Error code
Failing device or problem found
20D00902
The blade server is starting from the
permanent (B) firmware code page.
20D1000A
The Hypervisor function to get or set
the time-of-day (TOD) reported an
error.
20D10004
The blade server failed to locate
service processor device-tree node.
20D10005
The blade server failed to restart.
20D10006
The blade server failed to restart a
partition.
20D10007
Partition firmware error before stdout
ready.
20D1000A
Server failed to send the
startup-failure message to the service
processor.
20D10010
Stack underflow from the Fibre
Channel adapter.
20EE000B
The blade server could not find the
operating system among the devices
in the boot list.
Note: The startup sequence is also
known as the boot list.
20EE000F
Unable to find the package node.
20EE0010
Unable to process the root vpd
method.
20EE0011
Unable to process the vpd method.
20EE0012
Unable to process the
mem-dimm-vpd method.
82
BladeCenter JS20 Type 8842: Installation and User's Guide
Suggested action
If the blade server was set to start from the primary (B)
firmware code page, this is an informational message.
If it was not, this indicates that the blade server was
unable to start from the backup (A) firmware code page.
Go to "Recovering the system firmware code" on page 96.
Have the blade server serviced.
Complete the following steps:
1. Check for firmware or system processor updates.
2. Replace the blade server. Contact a service support
representative for assistance.
Perform the system checkout procedure. See "System
checkout" on page 64.
Perform the system checkout procedure. See "System
checkout" on page 64.
Perform the system checkout procedure. See "System
checkout" on page 64.
Perform the system checkout procedure. See "System
checkout" on page 64.
Perform the system checkout procedure. See "System
checkout" on page 64.
1. Check the http://www.ibm.com/pc/support/ Web site for
microcode updates for the Fibre Channel adapter.
Apply the latest update, if one is available.
2. If an update is not available, contact a system
administrator for assistance.
3. Perform the system checkout procedure. See "System
checkout" on page 64.
v If you have not installed an operating system on the
blade server, install it now.
v If you have installed an operating system on the blade
server, make sure that the startup sequence contains at
least one device with a valid operating-system startup
image.
If the problem remains, have the blade server serviced.
Contact a service support representative for assistance.
Perform the system checkout procedure. See "System
checkout" on page 64.
Perform the system checkout procedure. See "System
checkout" on page 64.
Perform the system checkout procedure. See "System
checkout" on page 64.
Perform the system checkout procedure. See "System
checkout" on page 64.