IBM eServer BladeCenter JS20 Installation And User Manual page 92

Type 8842
Hide thumbs Also See for eServer BladeCenter JS20:
Table of Contents

Advertisement

Checkpoint code
Description
E210
Load and relocate the hardware
isolation layer (HIL).
E211
CRC check of the image in flash
RAM.
E212
Get processor status and presence.
E213
Memory initialization.
E214
Pattern 1 memory test.
E215
Pattern 2 memory test.
E216
Clear memory.
E217
Setup DMA address re-mapping logic
(DART), HIL base, and storage
description register 1 (SDR1).
76
BladeCenter JS20 Type 8842: Installation and User's Guide
Suggested action
1. Perform the system checkout procedure. See
"System checkout" on page 64.
2. This error indicates that you might have a problem
with the system board. Contact a service support
representative for more information.
1. Perform the system checkout procedure. See
"System checkout" on page 64.
2. This error indicates that you might have a problem
with the system board. Contact a service support
representative for more information.
1. Perform the system checkout procedure. See
"System checkout" on page 64.
2. This error indicates that you might have a problem
with the system board. Contact a service support
representative for more information.
1. Make sure that the DIMMs are correctly installed
and seated; then, restart the blade server.
2. Start the blade server from the backup flash image
to recover the primary image.
3. This error indicates that you might have a problem
with the system board. Contact a service support
representative for more information.
1. Make sure that the DIMMs are correctly installed
and seated; then, restart the blade server.
2. Start the blade server from the backup flash image
to recover the primary image.
3. This error indicates that you might have a problem
with the system board. Contact a service support
representative for more information.
1. Make sure that the DIMMs are correctly installed
and seated; then, restart the blade server.
2. Start the blade server from the backup flash image
to recover the primary image.
3. This error indicates that you might have a problem
with the system board. Contact a service support
representative for more information.
1. Make sure that the DIMMs are correctly installed
and seated; then, restart the blade server.
2. Start the blade server from the backup flash image
to recover the primary image.
3. This error indicates that you might have a problem
with the system board. Contact a service support
representative for more information.
1. Perform the system checkout procedure. See
"System checkout" on page 64.
2. This error indicates that you might have a problem
with the system board. Contact a service support
representative for more information.