The Red Led I Sconstantly Lit - Mavix MediaRacer 100 User Manual

Surveillance multimedia gateway
Table of Contents

Advertisement

? Keep the spacebar depressed while the
system is booting. This causes the
MediaRacer® Service Software main
menu to be displayed.
? Select option 1 from the main menu to
display the system settings menu. Verify
that the Console I/O value is defined as
Enable. Enable value means that access to
all MediaRacer® Service software
options and the Application Log Screen
are enabled and visible.
T
R
LED I
HE
ED
S
Fault description:
After the MediaRacer® 100 unit has been connected to the power source, the red FLT
LED stays lit.
1. Connect a computer with a built -in HyperTerminal application to the
MediaRacer® 100 unit. Activate the MediaRacer® Service Software main
menu and verify that:
? Operation mode is set to Application.
? The BIST value is set to Disable.
2. Reboot the MediaRacer® 100 unit.
3. After rebooting the unit, verify that initialization messages are displayed on
screen and that the "Station" prompt is displayed upon completion of the
initialization process.
MediaRacer® 100 [Preliminar y]
---MAVIX---
C
L
ONSTANTLY
IT
71