Operation
10.
Select START. Using the keypad, enter 45, then press <Enter> to set the
starting phase angle to 45°.
11.
Select TIME, enter 1 for a duration of 1 millisecond, then press <Enter>. Note
that the instrument automatically calculates the STOP phase angle value (in this
case, 66.6°).
12.
Select AMPL, enter 10 for 10 volts, then press <Enter>.
13.
Press <Menu> to return to the WAVEFORM Menu.
WAVEFORM
LOAD
EDIT
VIEW
SAVE
DELETE
14.
Select VIEW to view the scratchpad, then press <Enter>. A waveshape similar
to the one illustrated below should be displayed on the scratchpad.
WAVEFORM
2
2
1
0
2
2
1
3-44
OUTPUT [OFF]
OUTPUT [OFF]
90
180
SW 5250A•SW 3500A•SW 1750A
270
Operation Manual