Instr (Instrument) Menu - Elgar SmartWave SW5250A Operation Manual

Switching amplifier
Table of Contents

Advertisement

SW 5250A•SW 3500A•SW 1750A
3.3.6

INSTR (Instrument) Menu

The INSTR menu allows you to:
Set the output range (156 or 312 volts).
Select either AC or AC+DC coupling.
Select current limit mode, either shutdown, foldback or time-out mode
(foldback for the time specified in the ITIMO field then shutdown mode).
Foldback mode is unavailable while SYSTEM/EXTERNAL/ LOW FREQ is on.
Select the time for the time-out mode.
Select the peak overvoltage limit.
Select amplifier parallel operation. When the Parallel mode is ON, only Phase A
will appear in the Program menu. Rear panel output power wiring must match
the Parallel mode selection.
CAUTION! Parallel mode must match the rear panel
output wiring before programming output amplitude.
INSTR Menu Status and Information Data:
Menu Item
RANGE
COUPLING
I MODE
I TIMO
V_LIM
PARALLEL
Operation Manual
M
AIN MENU
PROGRAM
MEASURE
WAVEFORM
SEQUENCE
INSTR
SYSTEM
Status and Information Line
[156V or 312V range]
[AC or AC+DC coupling]
[supervisory current mode]
[current limit time-out]
[peak voltage limit]
[parallel output amplifiers]
OUTPUT [OFF]
RANGE
COUPLING
I MODE
I TIMO
V_LIM
PARALLEL
Range
156V / 312V
AC / AC+DC
Shutdown / Foldback / Time-Out
100–9999 ms
20–255 Vpk/ 40–510 Vpk
On / Off
Operation
3-23