WAVEFORM
LOAD
EDIT
VIEW
SAVE
DELETE
Displays library of waveforms
6.
Press <Enter> to load the sine waveshape into scratchpad memory. The
message, [waveform successfully loaded], will indicate that the waveform is now
in scratchpad memory.
7.
Press <Menu> to return to the WAVEFORM Menu.
8.
Use either the Knob or the Up/Down Arrow keys to select the EDIT sub-menu,
then either press <Enter> or the Right Arrow key. The EDIT menu will be
displayed.
WAVEFORM
LOAD
EDIT
VIEW
SAVE
DELETE
9.
Select Vrms. Enter 120, then press <Enter> to set the RMS voltage to 120
volts.
Operation Manual
OUTPUT [OFF]
FUNC
Sine
OUTPUT [OFF]
60.00
FREQ
120.00
Vrms
45.00
START
1.00
TIME
66.60
STOP
10.00
AMPL
Operation
Hz
V
Deg
ms
Deg
V
3-43