Maximum Link Attempts set to 15
Other values at default settings
When the scanner goes out of range, 15 attempts are made to link to the
base unit. Each attempt consists of approximately 5 seconds of active time
followed by 3 seconds of idle time. After 15 cycles (8*15 =120), or about 2
minutes, the scanner stops trying to connect to the base, but retains any
bar codes that may have been saved in batch mode. After one hour, the
scanner powers off and batch mode data is lost.
Auto Reconnect Mode set to 0
Maximum Link Attempts set to 15
Other values at default settings
When the scanner goes out of range, no action is taken to relink. When
the scanner's button is pressed, 15 attempts are made to link to the base.
Each attempt consists of approximately 5 seconds of active time followed
by 3 seconds of idle time. After 15 cycles (8*15 =120), or about 2 minutes,
the scanner stops trying to connect to the base, but retains any bar codes
that may have been saved in batch mode. After one hour, the scanner
powers off and batch mode data is lost. Refer to
Mode, page 3-23, to review other events that can start the relink process.

Reset Scanner and Base

After changing settings, you may need to reset your scanner and base. Scan
the Reset Base bar code and wait for the scanner to unlink and relink to a base.
Once that is done, scan the Reset Scanner bar code and wait for the base to
unlink and relink to the scanner.
Reset Scanner
Auto Reconnect
: * : R E S E T _ . ³
Reset Base
3 - 25